ubuntu@ubuntu:~$ sudo smartctl -a /dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-42-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST640LM001 HN-M640MBB
Serial Number: S2ULJ9DC609222
LU WWN Device Id: 5 0004cf 207c6032e
Firmware Version: 2AR10002
User Capacity: 640,135,028,736 bytes [640 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Jul 29 22:12:00 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 8520) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 142) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 4496
2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3471
4 Start_Stop_Count 0x0032 087 087 000 Old_age Always - 13252
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 18851
10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 086 086 000 Old_age Always - 14750
12 Power_Cycle_Count 0x0032 087 087 000 Old_age Always - 13194
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 576
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
194 Temperature_Celsius 0x0002 064 051 000 Old_age Always - 28 (Min/Max 15/49)
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 2444
223 Load_Retry_Count 0x0032 086 086 000 Old_age Always - 14750
225 Load_Cycle_Count 0x0032 094 094 000 Old_age Always - 68532
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 275
SMART Error Log Version: 1
ATA Error Count: 2643 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2643 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 08 10 e0 00 00:00:06.070 READ DMA
c8 00 08 00 08 00 e0 00 00:00:06.070 READ DMA
ef 10 02 00 00 00 a0 00 00:00:06.070 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:00:06.070 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:00:06.070 IDENTIFY DEVICE
Error 2642 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 08 10 e0 00 00:00:06.068 READ DMA
c8 00 08 f0 07 10 e0 00 00:00:06.068 READ DMA
25 00 08 f0 7f 85 e0 00 00:00:06.068 READ DMA EXT
c8 00 08 80 07 10 e0 00 00:00:06.068 READ DMA
25 00 08 80 7f 85 e0 00 00:00:06.068 READ DMA EXT
Error 2641 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 08 10 e0 00 00:00:06.036 READ DMA
ef 10 02 00 00 00 a0 00 00:00:06.036 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:00:06.036 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:00:06.036 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:00:06.036 SET FEATURES [Set transfer mode]
Error 2640 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 08 10 e0 00 00:00:06.034 READ DMA
25 00 08 f0 7f 85 e0 00 00:00:06.034 READ DMA EXT
25 00 08 80 7f 85 e0 00 00:00:06.034 READ DMA EXT
c8 00 20 08 00 00 e0 00 00:00:06.034 READ DMA
c8 00 08 00 00 00 e0 00 00:00:06.034 READ DMA
Error 2639 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 08 10 e0 00 00:00:06.033 READ DMA
ef 10 02 00 00 00 a0 00 00:00:06.033 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:00:06.033 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:00:06.033 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:00:06.033 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 18850 1050624
# 2 Extended offline Completed: read failure 90% 18850 1050624
# 3 Extended offline Completed: read failure 90% 18850 1050624
# 4 Extended offline Completed: read failure 90% 18846 1050624
# 5 Extended offline Completed: read failure 90% 18846 1050624
# 6 Extended offline Completed: read failure 90% 18844 1050624
# 7 Extended offline Completed: read failure 90% 18844 1050624
# 8 Extended offline Completed: read failure 90% 18844 1050624
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed_read_failure [90% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Test will complete after Thu Jul 29 23:04:27 2021 UTC
mas notei que esse (1 0 0 Completed_read_failure [90% left] (0-65535)) não está saindo mais dessa quantia desde então até mesmo quando executei o teste ontem, isto é normal constar? o que só mudou foi quando executei este teste várias vezes após ter interrompido algumas vezes quando dei o comando: sudo smartctl -l selftest /dev/sda ... Como saber pelo terminal o término do teste? Hoje também ia instalar por cima da minha partição /dev/sda atual novamente uma formatação original de fábrica daí apareceu uma tela que até consta que a partição ainda mantém a mesma capacidade de tamanho e uso, seria uma boa idéia criar outra partição junto com essa corrompida para tentar resgatar os dados?
Por enquanto no resumo esse foi o resultado após ter inicializado e interrompido o teste algumas vezes por não ter notado o progresso:
ubuntu@ubuntu:~$ sudo smartctl -l selftest /dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-42-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 18850 1050624
# 2 Extended offline Completed: read failure 90% 18850 1050624
# 3 Extended offline Completed: read failure 90% 18850 1050624
# 4 Extended offline Completed: read failure 90% 18846 1050624
# 5 Extended offline Completed: read failure 90% 18846 1050624
# 6 Extended offline Completed: read failure 90% 18844 1050624
# 7 Extended offline Completed: read failure 90% 18844 1050624
# 8 Extended offline Completed: read failure 90% 18844 1050624
Daí agora (20:12) o teste terminou e está a mesma coisa aquela saída